ZHANG Lina, WANG Mingyi, CONG Dianxia, DING Shuyan, CONG Rinan, YUE Jinyong, GENG Jianli, HU Chengjin. Rapid, specific and sensitive detection of Vibrio vulnificus by loop-mediated isothermal amplification targeted to vvhA gene[J]. Acta Oceanologica Sinica, 2018, 37(4): 83-88. doi: 10.1007/s13131-018-1182-8
Citation: ZHANG Lina, WANG Mingyi, CONG Dianxia, DING Shuyan, CONG Rinan, YUE Jinyong, GENG Jianli, HU Chengjin. Rapid, specific and sensitive detection of Vibrio vulnificus by loop-mediated isothermal amplification targeted to vvhA gene[J]. Acta Oceanologica Sinica, 2018, 37(4): 83-88. doi: 10.1007/s13131-018-1182-8

Rapid, specific and sensitive detection of Vibrio vulnificus by loop-mediated isothermal amplification targeted to vvhA gene

doi: 10.1007/s13131-018-1182-8
  • Received Date: 2017-03-27
  • Vibrio vulnificus is an estuarine bacterial pathogen for human. The rapid, specific and sensitive detection of V. vulnificus is urgently needed for early disease diagnosis and timely treatment of V. vulnificus infection. In the study, a loop-mediated isothermal amplification (LAMP) technique was developed for V. vulnificus detection with a set of primers, composed of two out primers and two inner primers targeted to vvhA gene. The optimal amplification temperature was 63℃ and the reaction only took 35 min. The amplification products could not only be detected by agarose gel electrophoresis with ladder-like pattern bands, but also could be visualized using calcein with naked eye directly. Forty-five strains were tested for the specificity of LAMP assay, and all the V. vulnificus strains were identified correctly while other strains were negative results. The sensitive of the new LAMP assay was 100-fold more sensitive than the conventional PCR. Meanwhile, all the V. vulnificus strains were detected correctly in spiked, clinical and environmental samples by the new LAMP assay. Compared with other well-known techniques, the new LAMP assay targeted to vvhA gene was extremely rapid, simple, sensitive and specific for V. vulnificus identification.
  • loading
  • Böer S I, Heinemeyer E A, Luden K, et al. 2013. Temporal and spatial distribution patterns of potentially pathogenic Vibrio spp. at recreational beaches of the German north sea. Microb Ecol, 65(4): 1052-1067
    Endo S, Komori T, Ricci G, et al. 2004. Detection of gp43 of Paracoccidioides brasiliensis by the loop-mediated isothermal amplification (LAMP) method. FEMS Microbiol Lett, 234(1): 93-97
    Hara-Kudo Y, Yoshino M, Kojima T, et al. 2005. Loop-mediated isothermal amplification for the rapid detection of Salmonella. FEMS Microbiol Lett, 253(1): 155-161
    Iwamoto T, Sonobe T, Hayashi K. 2003. Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M. avium, and M. intracellulare in sputum samples. J Clin Microbiol, 41(6): 2616-2622
    Jaroenram W, Kiatpathomchai W, Flegel T W. 2009. Rapid and sensitive detection of white spot syndrome virus by loop-mediated isothermal amplification combined with a lateral flow dipstick. Mol Cell Probes, 23(2): 65-70
    Jones E H, Feldman K A, Palmer A, et al. 2013. Vibrio infections and surveillance in Maryland, 2002–2008. Public Health Rep, 128(6): 537-545
    Kim H R, Rho H W, Jeong M H, et al. 1993. Hemolytic mechanism of cytolysin produced from V. vulnificus. Life Sci, 53(7): 571-577
    Kim J R, Oh D R, Cha M H, et al. 2008. Protective effect of polygoni cuspidati radix and emodin on Vibrio vulnificus cytotoxicity and infection. J Microbiol, 46(6): 737-743
    Lee S E, Ryu P Y, Kim S Y, et al. 2004. Production of Vibrio vulnificus hemolysin in vivo and its pathogenic significance. Biochem Biophys Res Commun, 324(1): 86-91
    Li Yongjun, Zheng Zejun, Zhao Yulong, et al. 2010. A culture-free method for detection of Vibrio vulnificus from coastal seawater based on loop-mediated isothermal amplification targeting vcgC gene. Acta Oceanol Sin, 29(2): 93-97
    Ma Y, Dai T, Serwadda A, et al. 2016. Detecting a novel Eriocheir sinensis reovirus by reverse transcription loop-mediated isothermal amplification assay. Lett Appl Microbiol, 63(5): 363-368
    Notomi T, Okayama H, Masubuchi H, et al. 2000. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res, 28(12): e63
    O’Hara C M, Sowers E G, Bopp C A, et al. 2003. Accuracy of six commercially available systems for identification of members of the family Vibrionaceae. J Clin Microbiol, 41(12): 5654-5659
    Richards G P, Nuñez A. 2006. Specificity of a Vibrio vulnificus aminopeptidase toward kinins and other peptidyl substrates. J Bacteriol, 188(6): 2056-2062
    Shinoda S, Miyoshi S I, Yamanaka H, et al. 1985. Some properties of Vibrio vulnificus hemolysin. Microbiol Immunol, 29(7): 583-590
    Srisuk C, Chaivisuthangkura P, Rukpratanporn S, et al. 2010. Rapid and sensitive detection of Vibrio cholerae by loop-mediated isothermal amplification targeted to the gene of outer membrane protein ompW. Lett Appl Microbiol, 50(1): 36-42
    Sugiyama H, Kashimoto T, Ueno S, et al. 2011. Relationship between localization on cellular membranes and cytotoxicity of Vibrio vulnificus hemolysin. PLoS One, 6(10): e26018
    Sun Jiachun, Zheng Jing, Wang Guiming, et al. 2012. Apoptotic effect of Vibrio vulnificus cytolysin on A549 human lung adenocarcinoma cells. Mol Med Rep, 5(3): 668-674
    Surasilp T, Longyant S, Rukpratanporn S, et al. 2011. Rapid and sensitive detection of Vibrio vulnificus by loop-mediated isothermal amplification combined with lateral flow dipstick targeted to rpoS gene. Mol Cell Probes, 25(4): 158-163
    Thompson F L, Iida T, Swings J. 2004. Biodiversity of vibrios. Microbiol Mol Biol Rev, 68(3): 403-431
    Yamazaki W, Ishibashi M, Kawahara R, et al. 2008a. Development of a loop-mediated isothermal amplification assay for sensitive and rapid detection of Vibrio parahaemolyticus. BMC Microbiol, 8: 163
    Yamazaki W, Seto K, Taguchi M, et al. 2008b. Sensitive and rapid detection of cholera toxin-producing Vibrio cholerae using a loop-mediated isothermal amplification. BMC Microbiol, 8: 94
    Yano A, Ishimaru R, Hujikata R. 2007. Rapid and sensitive detection of heat-labile I and heat-stable I enterotoxin genes of enterotoxigenic Escherichia coli by loop-mediated isothermal amplification. J Microbiol Methods, 68(2): 414-420
    Yeh H Y, Shoemaker C A, Klesius P H. 2005. Evaluation of a loop-mediated isothermal amplification method for rapid detection of channel catfish Ictalurus punctatus important bacterial pathogen Edwardsiella ictaluri. J Microbiol Methods, 63(1): 36-44
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (966) PDF downloads(715) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return